Opis
The OPC application need not to be changed or affected for redundance connections to the controllers.

During the start of the data aquisition both connections will be created, established and checked. The data will be handled over one connection only preventing the controller from overloaded. This connection now is the master connection.
If the master connection does not respond in the requested time or it breaks, all items will be switched active on the second connection. If data are arriving now it becomes the master connection. The previous connection becomes slave, all items will be inactivated on it. None of the items will give a quality error to the OPC client. In the diagnostics logger the switching will be listed.
Only if all connections will be disturbed the elements will deliver bad quality. The OPC client can check the switching connection over the item "System.Topics..Redundancy", the value will change.
If the slave connection will fail this will be written into the diagnostics logger. Additionally the item "System.Topics..Status" will be set to failure.

On redundancy with three connections in case of failure of the master connection, some items are switched active on both slave connections. The faster connection wins and will become master, all of the rest items will be used on it. The more slowly connection goes into the slave state again.
Over the item "Redundancy" it can be checked which connection actually is the master. The items "Status1" and "Status2" (optionally "Status3" or more) are showing the actual state of the connections. They should be all zero if all connections exists.
Writing to the item "Redundancy" will switch the master immediately. This is for test purposes or for mainenance.
The jitter during switching the redundancy connection sets together

Monitoring timeout - the application timeout. It should be the controller reaction time multiplied by three, but minimum of one second.
Port komunikacyjny
tani
Akcesoria
100-0001-01 - Redundancy
100-0001-01Redundancy
100-0001-02 - OPC Server Addons 1000 connections
100-0001-02OPC Server Addons 1000 connections
101-0001-01 - OPC Server Standard Basis 50 poł 10000 zm
101-0001-01OPC Server Standard Basis 50 poł 10000 zm
101-0001-02 - OPC Server Addons 200 connections, 1.000.000 items
101-0001-02OPC Server Addons 200 connections, 1.000.000 items
101-0011-01 - OPC Server Standard Siemens 50 poł 10000 zm
101-0011-01OPC Server Standard Siemens 50 poł 10000 zm
101-0011-02 - OPC Server Addons Siemens
101-0011-02OPC Server Addons Siemens
101-0021-01 - OPC Server Standard Rockwell 50 poł 10000 zm
101-0021-01OPC Server Standard Rockwell 50 poł 10000 zm
101-0021-02 - OPC Server Addons Rockwell
101-0021-02OPC Server Addons Rockwell
101-0031-01 - OPC Server Standard De Luxe 50 poł 10000 zm
101-0031-01OPC Server Standard De Luxe 50 poł 10000 zm
101-0041-01 - OPC Server Standard De Luxe + OSI/H1 100 poł 10000 zm
101-0041-01OPC Server Standard De Luxe + OSI/H1 100 poł 10000 zm
101-0111-01 - OPC Server Minimum S7 2 poł 1000 zm
101-0111-01OPC Server Minimum S7 2 poł 1000 zm
101-0121-01 - OPC Server Minimum Rockwell 2 poł 1000 zm
101-0121-01OPC Server Minimum Rockwell 2 poł 1000 zm
104-0001-01 - PLC Engine Standard Basis 50 poł 10000 zm 100 tab
104-0001-01PLC Engine Standard Basis 50 poł 10000 zm 100 tab
104-0001-02 - PLC Engine Addons databases 4 DB
104-0001-02PLC Engine Addons databases 4 DB
104-0001-03 - PLC Engine Addons SAP104-0001-03PLC Engine Addons SAP
104-0001-04 - PLC Engine Addons OEE104-0001-04PLC Engine Addons OEE
104-0001-05 - PLC Engine Addons 10000 logic tables
104-0001-05PLC Engine Addons 10000 logic tables
104-0011-01 - PLC Engine Standard Siemens 50 poł 10000 zm 100 tab
104-0011-01PLC Engine Standard Siemens 50 poł 10000 zm 100 tab
104-0021-01 - PLC Engine Standard Rockwell 50 poł 10000 zm 100 tab
104-0021-01PLC Engine Standard Rockwell 50 poł 10000 zm 100 tab
104-0031-01 - PLC Engine Standard De Luxe 50 poł 10000 zm 100 tab
104-0031-01PLC Engine Standard De Luxe 50 poł 10000 zm 100 tab
104-0041-01 - PLC Engine Standard De Luxe + OSI/H1 100 poł 10000 zm 100 tab
104-0041-01PLC Engine Standard De Luxe + OSI/H1 100 poł 10000 zm 100 tab
104-0101-01 - PLC Engine Minimum 2 connections  Basis 2 poł 1000 zm 10 tab
104-0101-01PLC Engine Minimum 2 connections Basis 2 poł 1000 zm 10 tab
104-0111-01 - PLC Engine Minimum 2 connections  Siemens 2 poł 1000 zm 10 tab
104-0111-01PLC Engine Minimum 2 connections Siemens 2 poł 1000 zm 10 tab
104-0121-01 - PLC Engine Minimum 2 connections  Rockwell 2 poł 1000 zm 10 tab
104-0121-01PLC Engine Minimum 2 connections Rockwell 2 poł 1000 zm 10 tab
104-0201-01 - PLC Engine Minimum plus Database Access Basis 2 poł 1000 zm 10 tab
104-0201-01PLC Engine Minimum plus Database Access Basis 2 poł 1000 zm 10 tab
104-0211-01 - PLC Engine Minimum plus Database Access Siemens 2 poł 1000 zm 10 tab
104-0211-01PLC Engine Minimum plus Database Access Siemens 2 poł 1000 zm 10 tab
104-0221-01 - PLC Engine Small plus Database Access Rockwell 1000 zm 25 tab104-0221-01PLC Engine Small plus Database Access Rockwell 1000 zm 25 tab
104-0301-01 - PLC Engine Small plus Database Access Basis 3000 zm 25 tab
104-0301-01PLC Engine Small plus Database Access Basis 3000 zm 25 tab
104-0311-01 - PLC Engine Small plus Database Access Siemens 3000 zm 25 tab
104-0311-01PLC Engine Small plus Database Access Siemens 3000 zm 25 tab