{\rtf1\ansi\ansicpg1252\uc0\deff0{\fonttbl {\f0\fswiss\fcharset0\fprq2 Arial;} {\f1\froman\fcharset2\fprq2 Symbol;}} {\colortbl;\red0\green0\blue0;\red255\green255\blue255;\red0\green0\blue255;} {\info{\*\hlinkbase e:\\Medaps\\CA01_Generate\\export\\CA01_ENG_INT_IK_05102004\\rtf\\}{\comment TX_RTF32 8.0.300.500}} \deftab708\paperw15309\paperh16840\margl1134\margt1134\margr3430\margb1338\pard\sb100\plain\f0\fs18 The TD 200 permits:\par\pard\fi-284\li284\sb60\tx284\plain\f1\fs18 \'b7\plain\f0\fs18\tab Display of message texts: \line up to 80 message texts (alarms) with max. 6 variables display current operating states, and can be optionally parameterized as requiring acknowledgment and additionally protected by a password. In addition, up to 64\~static messages also with up to 6 variables can be configured. System texts are stored in English, German, French, Spanish and Italian in the unit. Various character sets can be selected, and messages can also be saved in the simplified Chinese character set.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab Display and modification of process parameters: \line Process parameters are output on the display and can be modified using the input keys, e.g., for temperature settings or modifications to speed.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab Setting of inputs and outputs: \line A memory bit is assigned to each of the 8 programmable function keys. These can then be set during operation, e.g., during commissioning, testing and diagnostics. It is then possible, for example, to control motors without having to install additional control elements in the system.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab Additional functions and features: \line For example, processing of floating-point numbers, symbols for bar-graph display, various data blocks for operation of several TD\~200 displays on one CPU, password protection for integrated SETUP menu and modified variables.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab Activation of TD\~200 editing mode by PLC: \line Variables embedded in messages can be edited directly without having to press the Enter key or to shift the cursor to the variable.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab Setting a PLC bit only with an STD\~200 key pressed: \line A PLC M-bit is set when pressing a function key, and deleted again when the key is released.\par\plain\f1\fs18 \'b7\plain\f0\fs18\tab New character set (Greek, Latin2, Turkish) to support additional foreign languages.\par\pard\sb60\sa20\plain\f0\fs18\b\cf3 Programming\par\pard\sb100\plain\f0\fs18 The configuration data of the TD 200 are saved in the S7-200's CPU. The message texts and configuration parameters are generated using the STEP 7-Micro/WIN programming software V4 and higher. Additional parameterization software is not required.\par Special data areas are reserved in the S7-200's CPU for data exchange with the TD 200. The TD 200 directly accesses the respectively required functions of the CPU via these data areas. Parameters can be set easily using a separate TD 200 Wizard in STEP 7 Micro/WIN\~V4 and higher.\par\pard\par }